The main concern is cracking and movement at the articulation joints on the north wall of the kitchen. Roof plumbing needs review by a registered plumber, and downpipes near the footing should discharge to stormwater.
Walk around the outside of the house to record visible defects for the owner before arranging repairs.

Photograph of the property looking west at the garage door.

View of the property at the entrance, looking north; a large tree was observed.

Non-compliant spreaders are to be reviewed by a registered plumber and rectified to NCC.

Non-compliant gutters and rainheads are to be reviewed by a registered plumber and rectified to NCC.

Significant cracking is present on the north wall of the kitchen. The articulation joint at the window is inadequate.

Significant movement is present at the articulation joint on the north wall at the kitchen window.

There is no flexible sealant to the articulation joints.

A drainage pipe is next to the house footing at the north wall of the study room.

Corroded downpipes are to be replaced.

The articulation joint at the garage south wall appeared to be filled with mortar.
Date, time and position recorded for each photograph. Positions come from the location service of the device at the moment of capture; accuracy is as reported by the device. Times and positions are not independently verified.
| Photo | Date and time | Source | Position |
|---|---|---|---|
| Stop 1 – Photo #1 | 29/08/2026 12:17 | Not recorded | Not recorded |
| Stop 2 – Photo #1 | 29/08/2026 12:22 | Not recorded | Not recorded |
| Stop 3 – Photo #1 | 29/08/2026 12:49 | Not recorded | Not recorded |
| Stop 4 – Photo #1 | 29/08/2026 12:51 | Not recorded | Not recorded |
| Stop 5 – Photo #1 | 29/08/2026 12:53 | Not recorded | Not recorded |
| Stop 6 – Photo #1 | 29/08/2026 12:56 | Not recorded | Not recorded |
| Stop 7 – Photo #1 | 29/08/2026 12:55 | Not recorded | Not recorded |
| Stop 8 – Photo #1 | 29/08/2026 12:59 | Not recorded | Not recorded |
| Stop 9 – Photo #1 | 29/08/2026 12:52 | Not recorded | Not recorded |
| Stop 10 – Photo #1 | 29/08/2026 13:01 | Not recorded | Not recorded |
End of Report
Report date: 2026-11-07
By: Inspector Name, Senior Structural Engineer, Reportai.au